Digital Junction Box converts signals from analogue load cells into digital ones, then further process these digital signals into meaningful readings like weight and totalized AD counts according to predefined parameters given to it. Samples of these parameters are capacity, division, decimal place, filter, auto zero tracking speed, weight units etc.
1)If you are using analogue load cells, DJB will bring you into convinient ditigal world.
-No more serveral times corners adjustment. Only one corner one time weight.
-No more indicators carried. Only one PC on hand.
-No more manual signals adjustment. Adjust automatically
Eccentric adjustment of multi load cells installations is now made easy. It calculates and compensates automatically the span gain of each individual load cell channel.
Each load cell channel is supported by an independent a 24 bit AD Converter, Special linearity compensation method plus all other technologies applied. These enable DJB to provide fast, stable and almost error-free weighing result anytime and anywhere.
Driver software is available to make setup nothing more than mouse clicks, selections on screen and numeric entries by finger tips.
2)If you are using digital load cells,give up the expensive digital load cells ,and DBJ will save your money and bring higher profit.
3)How is DJB(ABS and stainless steel housing is avalible) connection
Analogue load cells + +PC hyper terminal
PC software (handfree version )
Shine-C remote display
PC 350 indicator
other indicator (with handfree-DJB protocal)
METROLOGY FUNCTIONS
- Individual Load Cell Channel On/Off
- Automatic and manual Eccentric and Span adjustment
- Independent Zero Calibration
- Single point or dual point calibration
- Odd Weight Calibration
- Free Capacity and Division Setting
- Linearity Compensation ON or OFF
- 8 x Initial Zero Range
- 6 x Manual Zero Range
- 9 x Auto Zero Tracking Range
- 6 x Stable Definitions
OPERATION FUNCTIONS
- Weight Reading
- Totalized or Individual AD Value Reading
- Manual Tare
- Manual Zero
OTHER SELECTABLE PARAMETERS
- 3 x Filter Intensity Mode
- 6 x Data Output Baud Rate
- 6 x Output Band Rate
- 2 x Weight Units
Transmission by RS232 or RS485
Model No. |
DJB-4 |
DJB-6 |
DJB-8 |
DJB-4SS |
DJB-6SS |
DJB-8SS |
No.s of Load Cell Channels |
4 |
6 |
8 |
4 |
6 |
8 |
Enclosure |
ABS Housing |
Stainless Steel Housing |
AD Converter |
1 x 24 bit Σ-Δ Converter/Channel |
Weight Units |
Metric (kg) and Imperial (lb) |
A/D Sampling Speed |
15 times/ second |
Max. Measuring Range |
15 mV / Channel |
Power VoltageRequirements |
External Power Adaptor = 9~ 12V DC, 800mA |
Load Cell Excitation Voltage |
5 VDC/Channel |
Min Load Cell Impedance |
350Ω/Channel |
Max Load Cell Impedance |
1000Ω/Channel |
Load Cell Connection |
4-wire Load Cell Connections |
Operation Environment |
-10 ~ 40oC. Non-condensed. R.H.≦ 85% |
Specifications subject to change prior to notice |
|